Evaluate the AutomationView desktop suite free for 30 days. No credit card required. Claim trial key →
arrow_back Back to Articles

Programming Safe Motion Control with PLCopen Safety Blocks

calendar_month
person Carvalho Raphael

Programming Safe Motion Control with PLCopen Safety Blocks

Learning
%%{init: {'theme':'dark', 'themeVariables': { 'background': '#001c38' }}}%%
flowchart LR
    id1["Light Curtain"] --> id2["SF_GuardMonitoring"]
    id2 --> id3["Safe Motion Logic"]
    id3 --> id4["MC_Stop"]
    
    style id1 fill:#2563eb,stroke:#ffffff,stroke-width:2px,color:#ffffff
    style id2 fill:#16a34a,stroke:#ffffff,stroke-width:2px,color:#ffffff
    style id3 fill:#dc2626,stroke:#ffffff,stroke-width:2px,color:#ffffff
    style id4 fill:#9333ea,stroke:#ffffff,stroke-width:2px,color:#ffffff
AutomationView Icon AutomationView

Mastering Safe Motion Control Logic

Implementing reliable functional safety in high-speed motion control systems is often complex. Rather than building custom logic for every new machine, engineers are increasingly adopting PLCopen Safety Blocks. This standardization significantly reduces engineering time and ensures compliance with global safety directives like IEC 61508.

In this guide, we dive into how you can effectively integrate PLCopen Safety Blocks with your motion control architectures to achieve reliable, deterministic, and safe operation on the plant floor.

The Convergence of Motion and Safety

Historically, safety circuits were hardwired outside the PLC, leading to cumbersome troubleshooting and limited diagnostic visibility. With the advent of integrated safety PLCs, safety logic now runs alongside standard control logic. When using PLCopen Safety Blocks within an IEC 61131-3 environment, you can seamlessly tie safety conditions (like an emergency stop or an open guard door) directly to motion instructions.

For example, if a worker breaches a safety scanner zone, a SF_GuardMonitoring block triggers. This block communicates its state to the motion system, executing an MC_Stop or initiating a Safe Torque Off (STO) to bring the servo axis to a controlled halt without cutting primary power prematurely.

flowchart TD
    sensor["Safety Sensor (e.g., E-Stop)"] --> sf_estop["SF_EStop Block"]
    sf_estop -->|Safe State Active| logic["Safety Logic Evaluation"]
    logic -->|Trigger Stop| mc_stop["MC_Stop / MC_Halt"]
    logic -->|Cut Torque| sto["Safe Torque Off (STO)"]
    mc_stop --> servo["Servo Drive"]
    sto --> servo

    style sensor fill:#2563eb,color:#ffffff
    style sf_estop fill:#16a34a,color:#ffffff
    style logic fill:#ca8a04,color:#ffffff
    style mc_stop fill:#dc2626,color:#ffffff
    style sto fill:#dc2626,color:#ffffff
    style servo fill:#9333ea,color:#ffffff

Real-World Challenges and Nuances

While the standard simplifies coding, field implementation isn’t always straightforward. One common issue is managing the reset behavior after a safety trip. A sudden reset can cause a servo to jerk aggressively if the position error has grown significantly during the Safe Operating Stop (SOS) state. Properly managing the transition from an MC_Stop state back to operational status requires carefully resetting the following error and re-enabling the axis via MC_Power.

Another nuance involves asynchronous execution times. Safety tasks generally run on a dedicated, high-priority deterministic cycle (e.g., 2ms), while standard motion logic might operate on a different cycle. Data exchange between these tasks must be robust to prevent race conditions or missed safety triggers.

Comparison: PLCopen Safety vs. Custom Logic

Feature PLCopen Safety Blocks Custom Safety Logic
Certification Pre-certified (TÜV, etc.) Requires extensive manual validation
Portability High (Vendor-independent standard) Low (Tied to specific platforms)
Diagnostics Built-in standardized diagnostic codes Varies depending on developer skill
Engineering Time Significantly reduced via reuse High initial development time

Best Practices for Implementation

  • Map I/O Directly to Safety Blocks: Avoid intermediate variables when mapping physical safety inputs to blocks like SF_EmergencyStop. This minimizes the risk of signal manipulation.
  • Understand the Reset Mechanism: Most PLCopen Safety Blocks require an explicit manual reset (a rising edge on the Reset input) to clear errors and acknowledge the return to a safe state.
  • Leverage Vendor Documentation: Even though the standard is universal, specific parameter limits and diagnostic codes might vary. Always consult the official PLCopen Safety specifications alongside your PLC manufacturer’s manual.

Conclusion and FAQ

Implementing PLCopen Safety Blocks is the most robust path toward scalable, compliant motion control safety. By understanding the interaction between safety states and motion commands, engineers can design machines that are both highly productive and unequivocally safe.

What is the difference between STO and SOS?

Safe Torque Off (STO) removes the power that generates torque, leaving the motor to coast. Safe Operating Stop (SOS) holds the motor at a standstill with active torque, monitoring the position to ensure no movement occurs.

Can I mix standard logic with safety blocks?

Yes, but standard logic cannot dictate safety actions. Safety signals can be read by standard logic for diagnostics (e.g., displaying an alarm on an HMI), but standard logic cannot override safety outputs.

To optimize your PLC programming workflow and standardize your projects across teams, check out our tools and templates on the AutomationView Store.

Share this article

Stay Updated with Learning

Get the latest articles and news delivered directly to your inbox.

Log in to Subscribe

You must be registered and logged in to manage subscriptions.

Recommended for you

Inside PROFINET IRT: A Comprehensive Configuration Guide for Motion Control

Learning
%%{init: {'theme':'dark', 'themeVariables': { 'background': '#001c38' }}}%%
flowchart LR
    A["PLC Sync Master"] -->|"Isochronous Clock"| B["Axis 1 (Slave)"]
    B -->|"Hardware Sync"| C["Axis 2 (Slave)"]
    style A fill:#0d9488,stroke:#fff,color:#fff
    style B fill:#2563eb,stroke:#fff,color:#fff
    style C fill:#2563eb,stroke:#fff,color:#fff
AutomationView Icon AutomationView
calendar_month

Inside PROFINET IRT: A Comprehensive Configuration Guide for Motion Control

When engineering high-speed motion control systems, standard real-time communication often falls short. In applications like robotics, CNC, or tightly coupled electronic gearing, a variance of a few milliseconds in communication can translate to mechanical collisions or significant product defects. Achieving precise coordination requires a hardware-synchronized, deterministic network architecture. This is where PROFINET IRT configuration comes […]

Read Article arrow_forward

Inside SIL 2 Ultrasonic Sensors: Revolutionizing Collaborative Robotics Safety

Automation News
%%{init: {'theme':'dark', 'themeVariables': { 'background': '#001c38' }}}%%
flowchart LR
    A["Standard Component"] -->|Certification Bottleneck| B["System-Level Safety"]
    C["SIL 2 Ultrasonic Sensors"] -->|Drop-In Integration| D["Component-Level Safety"]
    style A fill:#dc2626,stroke:#f87171,stroke-width:2px,color:#ffffff
    style B fill:#dc2626,stroke:#f87171,stroke-width:2px,color:#ffffff
    style C fill:#16a34a,stroke:#4ade80,stroke-width:2px,color:#ffffff
    style D fill:#16a34a,stroke:#4ade80,stroke-width:2px,color:#ffffff
AutomationView Icon AutomationView
calendar_month

Inside SIL 2 Ultrasonic Sensors: Revolutionizing Collaborative Robotics Safety

Key Takeaways: System-wide safety certification has historically bottlenecked collaborative robotics (cobot) integration on the plant floor. New breakthroughs in 2026 introduce 3D ultrasonic sensors with native SIL 2 and PL d safety ratings. Engineers can now achieve component-level safety, bypassing the need for exhaustive, custom system certifications. The End of System-Level Bottlenecks Deploying collaborative robotics […]

Read Article arrow_forward