Evaluate the AutomationView desktop suite free for 30 days. No credit card required. Claim trial key →
arrow_back Back to Articles

Inside Beckhoff MX-System: The Cabinet-Free Automation Guide

calendar_month
person Carvalho Raphael

Inside Beckhoff MX-System: The Cabinet-Free Automation Guide

Learning
%%{init: {'theme':'dark', 'themeVariables': { 'background': '#001c38' }}}%%
flowchart LR
    A["Power Feed Module"] --> B["MX Baseplate"]
    B --> C["IPC TwinCAT Runtime"]
    B --> D["Motion Drive Module"]
    B --> E["Decentralized I/O"]
    C -->|EtherCAT| D
    C -->|EtherCAT| E
AutomationView Icon AutomationView

Control cabinet assembly remains one of the largest labor bottlenecks in machine building. Traditional automation panels demand extensive manual layout, point-to-point wiring, DIN-rail terminal blocks, and active air conditioning units to dissipate thermal loads. The Beckhoff MX-System shifts this paradigm by replacing sheet-metal enclosures with an IP67-rated, modular platform mounted directly on the machine frame.

By standardizing electrical and mechanical interfaces on a ruggedized aluminum backplane, engineers can reduce commissioning hours from days to a single shift while eliminating wiring errors entirely.

Key Takeaways for Machine Designers

  • Complete Cabinet Elimination: Housing, power distribution, IPCs, servo drives, safety relays, and I/O modules reside directly in IP67-rated modules.
  • Internal EtherCAT Backplane: High-speed deterministic communication runs through sealed internal PCB backplanes, removing external communication cabling between core modules.
  • Passive Conduction Cooling: Heat dissipates directly through the heavy-duty aluminum baseplate into the machine chassis, eliminating panel fans and climate control units.
  • Rapid Assembly: Standardized plug-and-lock interfaces cut assembly and testing time by up to 80% compared to traditional cabinet builds.

The Mechanical and Electrical Architecture of the MX-System

The core foundation of the Beckhoff MX-System is a precision-machined aluminum baseplate containing integrated data and power buses. The baseplate acts as both the structural backbone and a high-efficiency thermal heatsink. Modules are secured using standard screws that establish IP67 water and dust seals while simultaneously engaging internal high-current contacts and EtherCAT communication lines.

Power routing is decoupled internally: 400V AC or 48V DC mains power supplies feed adjacent servo drives through continuous internal copper busbars, while a separate 24V DC logic rail powers the IPC and safety controllers. All field connections (motors, sensors, encoders) connect externally via standard IP67 M8, M12, or push-pull connectors.

flowchart TD
    subgraph Baseplate["MX-System IP67 Baseplate (Passive Heat Sink)"]
        PS["Power Feed Module (400V AC / 48V DC)"]
        IPC["IPC Module (TwinCAT Runtime)"]
        DRV["Servo Drive Modules (OCT Feedback)"]
        IO["I/O Expansion Modules (Digital/Analog/Safety)"]
    end
    Sensors["Machine Sensors (M12/M8)"]
    Motors["Servomotors (One Cable Technology)"]
    PS -->|Internal DC Bus| DRV
    PS -->|24V Control Power| IPC
    PS -->|24V Field Power| IO
    IPC -->|Internal EtherCAT Bus| DRV
    IPC -->|Internal EtherCAT Bus| IO
    DRV -->|One Cable Technology (OCT)| Motors
    IO -->|M12 / M8 Shielded Cables| Sensors

Field Realities: Thermal and Installation Considerations

Deploying control hardware directly on machine frames introduces mechanical and environmental challenges that engineers must address during design:

  • Thermal Management: Without fans or cabinet air conditioners, module heat relies on conductive transfer into the baseplate and surrounding machine frame. When planning dense drive clusters, verify continuous frame mass and ambient air circulation to maintain junction temperatures within safe operating limits.
  • Vibration and Shock Resistance: Direct machine mounting exposes electronics to mechanical harmonics. The MX-System is rated for severe industrial vibration profiles, but structural mounting points must avoid resonant frequencies generated by heavy presses or unbuffered linear actuators.
  • Torque Consistency on Seals: Ensuring IP67 ingress protection requires uniform fastening torque across all module securing screws. Uneven tightening can compromise elastomer seals and expose internal bus traces to coolant spray or washdown fluids.

Cabinet Build vs. Beckhoff MX-System Architecture

The following table outlines the operational differences between conventional cabinet builds and the decentralized MX-System:

Architecture Attribute Conventional Control Cabinet Beckhoff MX-System
Assembly and Wiring Time 16 to 40 hours per machine 1 to 2 hours (plug-in modules)
Footprint on Factory Floor Requires dedicated floor clearance Zero floor space (machine-mounted)
Wiring Error Risk High (manual terminal wiring) Zero (keyed PCB backplane sockets)
Cooling Requirements Panel fans, heat exchangers, AC Passive conduction via baseplate
Module Replacement (MTTR) 2 to 4 hours (wire tracing required) Under 10 minutes (hot-swap modules)
International Compliance Requires custom UL 508A / CE certification Pre-certified modular components

TwinCAT 3 Integration and Software Workflow

From an engineering perspective, the Beckhoff MX-System runs on standard Beckhoff industrial PC hardware supporting TwinCAT 3 (including TwinCAT/BSD and real-time Windows). I/O topology scanning, EtherCAT diagnostics, and motion axis configurations behave identically to standard DIN-rail IPC systems.

Machine builders can design and validate power budgets and module layouts before purchasing hardware using the web-based MX-System Designer tool. This tool calculates baseplate slot allocations, current limits, and cable branch lengths directly against machine CAD models.

Standardize PLC Logic Before Hardware Delivery

Transitioning to modular hardware works best when your software sequences are equally modular. Stop sketching complex state machines on whiteboards or debugging sequence interlocks on the shop floor.

Explore AutomationView tools and software to model, simulate, and validate sequential function charts (SFC) and state logic before cutting metal or mounting baseplates.

Frequently Asked Questions (FAQ)

Can the Beckhoff MX-System handle high-power servo applications?

Yes. The MX-System power supply modules support up to 63A continuous feed at 400V AC, capable of driving multiple servo axes simultaneously via internal DC intermediate circuits.

How does maintenance work if an internal module fails?

Because all internal connections use keyed backplane sockets, technicians isolate mains power, loosen the module mounting screws, and swap the unit in minutes without touching intermediate wiring.

Is the MX-System suitable for food and beverage washdown environments?

Yes. With IP67 sealing, anodized aluminum baseplates, and chemical-resistant elastomer gaskets, the system withstands standard industrial washdown procedures without requiring secondary protective hoods.

Share this article

Stay Updated with Learning

Get the latest articles and news delivered directly to your inbox.

Log in to Subscribe

You must be registered and logged in to manage subscriptions.

Recommended for you

Inside Omron S8NR: The Shift to IP67 Decentralized Power

Automation News
%%{init: {'theme':'dark', 'themeVariables': { 'background': '#001c38' }}}%%
flowchart LR
    subgraph central ["Centralized Architecture"]
      A["Main Cabinet PS"] -->|Long DC Cable| B["Remote I/O Block"]
    end
    subgraph decentral ["IP67 Decentralized Architecture"]
      C["Local AC Feed"] -->|Short Drop| D["Omron S8NR (IP67)"]
      D -->|Short DC Cable| E["Local I/O & Sensors"]
    end
    style A fill:#dc2626,color:#ffffff,stroke:#333,stroke-width:2px
    style D fill:#16a34a,color:#ffffff,stroke:#333,stroke-width:2px
AutomationView Icon AutomationView
calendar_month

Inside Omron S8NR: The Shift to IP67 Decentralized Power

Historically, industrial machine design relied on massive centralized control cabinets packed with power supplies, contactors, and relays. Every sensor, actuator, and remote I/O block required a long, complex cable run back to this central hub. This architecture introduced significant wiring costs, increased the risk of voltage drop, and created thermal management headaches for panel builders. […]

Read Article arrow_forward

Inside Single Pair Ethernet (SPE): Architecting 10BASE-T1L for PLC Networks

Learning
%%{init: {'theme':'dark', 'themeVariables': { 'background': '#001c38' }}}%%
flowchart LR
    A[Main PLCnStandard Ethernet] --> B(SPE Switch / PSE)
    B -- "10BASE-T1L + PoDL" --> C[SPE Field Sensor]
    B -- "10BASE-T1L + PoDL" --> D[SPE Actuator]
    style A fill:#2e5b8e,color:#fff
    style B fill:#e67e22,color:#fff
    style C fill:#27ae60,color:#fff
    style D fill:#27ae60,color:#fff
AutomationView Icon AutomationView
calendar_month

Inside Single Pair Ethernet (SPE): Architecting 10BASE-T1L for PLC Networks

Replacing legacy 4-20mA systems with IP-based networks has always been a challenge in the process industries due to distance limits. Single Pair Ethernet (SPE), specifically the IEEE 802.3cg 10BASE-T1L standard, fundamentally changes this by delivering power and 10 Mbps Ethernet over a single twisted pair up to 1,000 meters. This shifts the automation paradigm from […]

Read Article arrow_forward