Walk into any legacy control room, and you’ll likely see operators squinting at screens packed with flashing red pumps and scattered data values. Without standardized HMI faceplates, interpreting plant floor conditions becomes a memory test rather than an intuitive process. Building a reusable faceplate isn’t just about saving development time; it’s about eliminating cognitive load when an alarm triggers at 3 AM.
Whether you’re migrating an old Wonderware application or deploying a new Ignition gateway, dropping custom-built graphics onto a screen one by one is no longer viable. Here are five practical strategies to design robust PLC graphics that align with high-performance HMI standards.
1. Abstract Your PLC Data Structures
The foundation of any robust faceplate is a well-structured User-Defined Data Type (UDT) inside the PLC. Before drawing a single graphic, you must abstract the data. Instead of binding individual tags (like Pump1_Start and Pump1_Speed) to your HMI elements, bind a single UDT structure (e.g., Pump_Control_UDT) to the entire faceplate instance.
This abstraction allows the SCADA system to utilize indirect addressing or tag substitution. When you drop a new faceplate onto a screen, you simply point it to the root tag of the equipment, and all nested properties automatically resolve. The hardest part here is usually getting mechanical engineers to agree on standard equipment profiles. If “Pump 1” has a VFD and “Pump 2” is a simple contactor, your UDTs need to account for both without bloating the data structure.
2. Implement Grayscale Backgrounds for High-Performance Design
To maximize operator response times, avoid vibrant colors for normal operating states. A sea of bright green pipes and blue tanks makes it nearly impossible to spot a red fault indicator quickly.
Switch to grayscale backgrounds and muted tones for standard equipment representation. Save high-contrast colors exclusively for abnormal situations or active alarms. It often takes operators a few weeks to adjust to the “boring” gray screens, but the drop in missed alarms usually justifies the transition.
flowchart TD
classDef normal fill:#94a3b8,stroke:#475569,stroke-width:2px,color:#fff
classDef alarm fill:#ef4444,stroke:#b91c1c,stroke-width:2px,color:#fff
classDef warn fill:#f59e0b,stroke:#b45309,stroke-width:2px,color:#fff
Start["Evaluate Equipment State"]:::normal --> Condition{Is State Normal?}
Condition -->|Yes| NormalState["Display Grayscale Graphic"]:::normal
Condition -->|Warning| WarnState["Highlight Yellow with Icon"]:::warn
Condition -->|Critical| AlarmState["Highlight Red with Blinking"]:::alarm
3. Utilize Consistent Navigation and Tabbed Interfaces
You shouldn’t clutter the main process overview. Use a compact symbol on the main graphic that opens a detailed popup faceplate when clicked. Inside this popup, use tabbed navigation to organize the properties logically.
| Tab Name | Primary Content | Target Audience |
|---|---|---|
| Operation | Start, Stop, Auto/Manual modes, Setpoints | Operators |
| Parameters | Tuning constants, Alarm limits, Scaling | Engineers |
| Diagnostics | Fault codes, Interlocks, Communication status | Maintenance |
Real-world tip: Keep the ‘Parameters’ and ‘Diagnostics’ tabs locked behind a security level. You don’t want an operator accidentally changing a PID tuning constant while trying to acknowledge a fault.
4. Embed Analog Context with Moving Analog Indicators
Displaying a raw number (e.g., “45.2 PSI”) forces the operator to memorize the acceptable range for that specific instrument. Instead, incorporate Moving Analog Indicators (MAI) or bullet graphs alongside digital values.
These visual tools provide immediate context. They show the current value relative to the operating range, high/low alarm limits, and the optimal setpoint—meaning an operator can look at a tank level and instantly know if it’s drifting towards a high-level trip.
5. Standardize Across Your SCADA Integration
If a pump faceplate on Line 1 opens a popup with the Start button on the left, Line 4 shouldn’t have the Start button on the right.
Develop a central graphics library within your SCADA software and stick to it. Any modifications to a faceplate should be made centrally and propagated out to all instances. This strict version control prevents “configuration drift” where graphics become fractured over years of ad-hoc maintenance.
Conclusion
Mastering HMI faceplates requires discipline on both the PLC and SCADA sides. By enforcing UDTs, shifting to grayscale layouts, and locking down your graphics library, you build applications that scale cleanly and operators actually want to use.
For more tools to accelerate your automation workflow, explore our professional resources and software at the AutomationView Store.
Stay Updated with HMI
Get the latest articles and news delivered directly to your inbox.
You must be registered and logged in to manage subscriptions.
Recommended for you
Essential ISA-101 HMI Standard Tips for Amazing Screens
HMI%%{init: {'theme':'dark', 'themeVariables': { 'background': '#001c38' }}}%%
flowchart LR
A[Legacy HMI] -->|Apply ISA-101| B(High-Performance Screens)
B --> C[Grayscale]
B --> D[Redundant Alarms]
B --> E[Simplified P&IDs]
C & D & E --> F[Safe & Efficient Operations]
Essential ISA-101 HMI Standard Tips for Amazing Screens
When operators first look at an ISA-101 HMI standard compliant screen, their most common complaint is that it looks “boring” or “broken.” The vibrant 3D pumps and spinning cooling fans of legacy SCADA systems are gone, replaced by flat, muted shapes on a gray background. But that dullness is entirely intentional. The goal isn’t to […]
5 Essential HMI Design Principles for Maximum Operator Efficiency
HMI%%{init: {'theme':'dark', 'themeVariables': { 'background': '#001c38' }}}%%
flowchart LR
A[Traditional HMI] -->|Visual Noise| B[Operator Fatigue]
C[ISA-101 High-Performance HMI] -->|Grayscale & Muted Tones| D[Situational Awareness]
D -->|Faster Diagnosis| E[Maximum Efficiency]
5 Essential HMI Design Principles for Maximum Operator Efficiency
Why Traditional HMIs Fail on the Plant Floor I once walked into a control room where every single pump on the SCADA screen was flashing bright green, while three separate red alarms were blinking furiously in the corner. The operator didn’t even blink. When the interface is a Christmas tree of 3D animations and saturated […]