Evaluate the AutomationView desktop suite free for 30 days. No credit card required. Claim trial key →

Category: HMI

Stay Updated with HMI

Get the latest articles and news delivered directly to your inbox.

Log in to Subscribe

You must be registered and logged in to manage subscriptions.

search

How to Design Colorblind-Friendly HMI Palettes for Industrial Control

HMI
%%{init: {'theme':'dark', 'themeVariables': { 'background': '#001c38' }}}%%
flowchart LR
    A["Operator Input"] -->|Color Deficient| B{"Process State"}
    B -->|Green Hue| C["Perceived as Gray"]
    B -->|Red Hue| D["Perceived as Gray"]
    C --> E["Safety Risk"]
    D --> E
    style A fill:#1e3a8a,stroke:#0f172a,color:#ffffff
    style B fill:#3b82f6,stroke:#0f172a,color:#ffffff
    style C fill:#94a3b8,stroke:#0f172a,color:#000000
    style D fill:#94a3b8,stroke:#0f172a,color:#000000
    style E fill:#ef4444,stroke:#7f1d1d,color:#ffffff
AutomationView Icon AutomationView
calendar_month

How to Design Colorblind-Friendly HMI Palettes for Industrial Control

Red means stop, green means go. It is a universal rule embedded in the minds of almost every industrial automation engineer. However, for approximately 8% of men and 0.5% of women operating machinery on the plant floor, distinguishing between a green “Running” indicator and a red “Fault” alarm is a daily struggle. Relying solely on […]

Read Article arrow_forward

Deep Dive: Mastering SCADA Trending and Historians for Process Visualization

HMI
%%{init: {'theme':'dark', 'themeVariables': { 'background': '#001c38' }}}%%
flowchart LR
    style PLC fill:#0d47a1,stroke:#0d47a1,stroke-width:2px,color:#ffffff
    style SCADA fill:#1565c0,stroke:#1565c0,stroke-width:2px,color:#ffffff
    style Hist fill:#1976d2,stroke:#1976d2,stroke-width:2px,color:#ffffff
    PLC["PLC Data Buffer"] -->|Real-Time| SCADA["HMI / SCADA Trending"]
    SCADA -->|Archiving| Hist["Process Historian DB"]
AutomationView Icon AutomationView
calendar_month

Deep Dive: Mastering SCADA Trending and Historians for Process Visualization

TL;DR: Differentiate live memory-buffered trends from long-term SQL/Time-Series storage to prevent HMI lag. Aggressive exception logging (deadbanding) saves massive database space but requires careful tuning to avoid missing transient spikes. Providing contextual overlays like setpoints and alarm limits transforms a meaningless squiggly line into actionable troubleshooting data. Pushing thousands of tags to a database without […]

Read Article arrow_forward

Deep Dive: Architecting HMI Navigation for Rapid Operator Response

HMI
%%{init: {'theme':'dark', 'themeVariables': { 'background': '#001c38' }}}%%
flowchart LR
    style A fill:#0d47a1,stroke:#0d47a1,stroke-width:2px,color:#ffffff
    style B fill:#1565c0,stroke:#1565c0,stroke-width:2px,color:#ffffff
    style C fill:#1976d2,stroke:#1976d2,stroke-width:2px,color:#ffffff
    A["Overview Display (Level 1)"] --> B["Process Area (Level 2)"]
    B --> C["Control Details (Level 3)"]
AutomationView Icon AutomationView
calendar_month

Deep Dive: Architecting HMI Navigation for Rapid Operator Response

Key Takeaways: Limit navigation depth to a strict three-click maximum to prevent operator disorientation during critical faults. Adopt the ISA-101 hierarchy to logically separate high-level overviews from granular equipment diagnostics. Use color strictly for abnormal states, keeping normal operations visually muted to instantly guide attention. When a reactor temperature hits a high-high alarm, the control […]

Read Article arrow_forward

Building a Resilient HMI Display Hierarchy: An Operations Deep Dive

HMI
%%{init: {'theme':'dark', 'themeVariables': { 'background': '#001c38' }}}%%
flowchart LR
    L1["Level 1: Overview (Plant Status)"] --> L2["Level 2: Unit Control (Operations)"]
    L2 --> L3["Level 3: Detail (Troubleshooting)"]
    L3 --> L4["Level 4: Diagnostics (I/O & Help)"]
    
    classDef l1 fill:#3b82f6,stroke:#1d4ed8,stroke-width:2px,color:#fff;
    classDef l2 fill:#10b981,stroke:#047857,stroke-width:2px,color:#fff;
    classDef l3 fill:#f59e0b,stroke:#b45309,stroke-width:2px,color:#fff;
    classDef l4 fill:#6b7280,stroke:#374151,stroke-width:2px,color:#fff;
    
    class L1 l1;
    class L2 l2;
    class L3 l3;
    class L4 l4;
AutomationView Icon AutomationView
calendar_month

Building a Resilient HMI Display Hierarchy: An Operations Deep Dive

TL;DR: A poorly structured SCADA screen causes cognitive overload during plant alarms. An ISA-101 compliant HMI display hierarchy separates information into four functional levels. Keep high-level dashboards separate from granular I/O diagnostic screens to improve operator response times. The Importance of SCADA Screen Architecture During a plant upset, an operator facing a poorly structured SCADA […]

Read Article arrow_forward

Mastering HMI Faceplates: 5 Proven Strategies

HMI
%%{init: {'theme':'dark', 'themeVariables': { 'background': '#001c38' }}}%%
flowchart LR
    classDef main fill:#0ea5e9,stroke:#0284c7,stroke-width:2px,color:#fff
    classDef block fill:#1e293b,stroke:#334155,stroke-width:2px,color:#f8fafc
    
    A["PLC Data Block"]:::block -->|Tag Binding| B["HMI Faceplate"]:::main
    B -->|Reusable Instance| C["Pump 1"]:::block
    B -->|Reusable Instance| D["Pump 2"]:::block
    B -->|Reusable Instance| E["Pump 3"]:::block
AutomationView Icon AutomationView
calendar_month

Mastering HMI Faceplates: 5 Proven Strategies

Walk into any legacy control room, and you’ll likely see operators squinting at screens packed with flashing red pumps and scattered data values. Without standardized HMI faceplates, interpreting plant floor conditions becomes a memory test rather than an intuitive process. Building a reusable faceplate isn’t just about saving development time; it’s about eliminating cognitive load […]

Read Article arrow_forward

Ultimate SCADA Alarm Management Tips for ISA-18.2

HMI
%%{init: {'theme':'dark', 'themeVariables': { 'background': '#001c38' }}}%%
flowchart LR
    A[Alarm Philosophy] --> B[Rationalize & Prioritize]
    B --> C[Dynamic Suppression]
    C --> D[High-Performance HMI]
    D --> E[Continuous Monitoring]
AutomationView Icon AutomationView
calendar_month

Ultimate SCADA Alarm Management Tips for ISA-18.2

Introduction to ISA-18.2 and Alarm Fatigue In a typical control room, an operator might be hit by a deluge of over 2,000 alarms per shift during a minor process upset. Most of these are nuisance alarms. When a SCADA system drowns operators in noise, genuine critical warnings get buried—often with catastrophic consequences. Effective SCADA Alarm […]

Read Article arrow_forward

Essential ISA-101 HMI Standard Tips for Amazing Screens

HMI
%%{init: {'theme':'dark', 'themeVariables': { 'background': '#001c38' }}}%%
flowchart LR
    A[Legacy HMI] -->|Apply ISA-101| B(High-Performance Screens)
    B --> C[Grayscale]
    B --> D[Redundant Alarms]
    B --> E[Simplified P&IDs]
    C & D & E --> F[Safe & Efficient Operations]
AutomationView Icon AutomationView
calendar_month

Essential ISA-101 HMI Standard Tips for Amazing Screens

When operators first look at an ISA-101 HMI standard compliant screen, their most common complaint is that it looks “boring” or “broken.” The vibrant 3D pumps and spinning cooling fans of legacy SCADA systems are gone, replaced by flat, muted shapes on a gray background. But that dullness is entirely intentional. The goal isn’t to […]

Read Article arrow_forward

5 Essential HMI Design Principles for Maximum Operator Efficiency

HMI
%%{init: {'theme':'dark', 'themeVariables': { 'background': '#001c38' }}}%%
flowchart LR
    A[Traditional HMI] -->|Visual Noise| B[Operator Fatigue]
    C[ISA-101 High-Performance HMI] -->|Grayscale & Muted Tones| D[Situational Awareness]
    D -->|Faster Diagnosis| E[Maximum Efficiency]
AutomationView Icon AutomationView
calendar_month

5 Essential HMI Design Principles for Maximum Operator Efficiency

Why Traditional HMIs Fail on the Plant Floor I once walked into a control room where every single pump on the SCADA screen was flashing bright green, while three separate red alarms were blinking furiously in the corner. The operator didn’t even blink. When the interface is a Christmas tree of 3D animations and saturated […]

Read Article arrow_forward