PLC Memory Guide: User-Defined Types (UDTs) vs Arrays

calendar_month
person Carvalho Raphael

PLC Memory Guide: User-Defined Types (UDTs) vs Arrays

Learning
%%{init: {'theme':'dark', 'themeVariables': { 'background': '#001c38' }}}%%
flowchart LR
    classDef arrayStyle fill:#2563eb,color:#ffffff,stroke:#1e40af,stroke-width:2px
    classDef udtStyle fill:#16a34a,color:#ffffff,stroke:#166534,stroke-width:2px

    subgraph memory_options ["Memory Options"]
        A["PLC Arrays"]:::arrayStyle -->|Index Based| B["Uniform Data"]
        C["PLC UDTs"]:::udtStyle -->|Tag Based| D["Heterogeneous Data"]
    end
AutomationView Icon AutomationView

Key Takeaways:

  • Arrays provide rapid, index-based access for uniform data types but lack contextual readability.
  • PLC User-Defined Types (UDTs) group heterogeneous data logically, mirroring real-world assets like motors and valves.
  • Proper memory structuring is critical for maintainability and reducing downtime on the plant floor.

The choice between arrays and PLC User-Defined Types (UDTs) is a constant architectural debate in industrial automation. Engineers frequently encounter spaghetti code inherited from older PLCs where 100-element integer arrays act as cryptic catch-alls for machine state. Structuring memory correctly from day one prevents this technical debt.

Understanding PLC Arrays

Arrays are continuous blocks of memory reserved for a single data type, such as INT, REAL, or BOOL. They are addressed using an index (e.g., TemperatureSensor[0] through TemperatureSensor[99]). Arrays shine when processing large batches of identical data through loops in Structured Text (ST).

What Are PLC User-Defined Types (UDTs)?

PLC User-Defined Types (UDTs) allow engineers to define custom data structures containing multiple native types. For example, a Motor_UDT might contain a BOOL for Run Command, a REAL for Speed Feedback, and an INT for Fault Code. When instantiated, the UDT creates a cohesive tag structure.

flowchart TD
    classDef udtStyle fill:#dc2626,color:#ffffff,stroke:#991b1b,stroke-width:2px
    classDef varStyle fill:#2563eb,color:#ffffff,stroke:#1e40af,stroke-width:2px

    subgraph motor_udt ["Motor UDT Structure"]
        A["Motor_1 (UDT)"]:::udtStyle
        A --> B["RunCommand (BOOL)"]:::varStyle
        A --> C["SpeedFeedback (REAL)"]:::varStyle
        A --> D["FaultCode (INT)"]:::varStyle
    end

The Real-World Nuance: Legacy Integration

On the plant floor, adopting PLC User-Defined Types (UDTs) often clashes with legacy SCADA systems or HMI faceplates expecting contiguous array blocks for optimized polling. A common paradox is mapping a beautifully structured UDT back into a flat array via block transfers just to appease an older OPC DA server. Engineers must balance modern structural elegance with the harsh reality of existing infrastructure.

Arrays vs. UDTs: Side-by-Side Comparison

Feature PLC Arrays PLC User-Defined Types (UDTs)
Data Types Homogeneous (Single type only) Heterogeneous (Mixed types allowed)
Readability Low (Requires external documentation for indices) High (Self-documenting tags)
Iteration Excellent (FOR/WHILE loops via index) Poor (Requires indirect addressing tricks)
Typical Use Case Shift registers, historical data buffers, PID arrays Equipment modeling (Motors, Valves, PID loops)

Level Up Your Architecture with AutomationView

Stop wrestling with cryptic arrays and disorganized memory tags when designing your machine logic. AutomationView allows you to build, visualize, and simulate complex state machines instantly, without needing physical hardware. Standardize your structures and validate your logic before ever touching a PLC. Explore the AutomationView Store to revolutionize your engineering workflow today.

Frequently Asked Questions

Can I put an Array inside a UDT?

Yes, most modern platforms (like Allen-Bradley ControlLogix or Siemens TIA Portal) allow arrays within a UDT, offering powerful ways to structure alarm histories or step sequences.

Do UDTs consume more memory than Arrays?

Yes, padding and alignment rules in PLCs often mean a UDT consumes slightly more memory than a tightly packed array, though this is rarely an issue in modern high-capacity controllers.

Share this article

Stay Updated with Learning

Get the latest articles and news delivered directly to your inbox.

Log in to Subscribe

You must be registered and logged in to manage subscriptions.

Recommended for you

Inside CIP Safety over EtherNet/IP: A Technical Guide

Learning
%%{init: {'theme':'dark', 'themeVariables': { 'background': '#001c38' }}}%%
flowchart LR
    A["Standard Controller"]:::bgBlue --> C["EtherNet/IP Switch"]:::bgSlate
    B["Safety Controller"]:::bgRed --> C
    C --> D["Standard I/O"]:::bgBlue
    C --> E["Safety I/O (SIL 3)"]:::bgRed

    classDef bgBlue fill:#2563eb,color:#ffffff,stroke-width:0px;
    classDef bgRed fill:#dc2626,color:#ffffff,stroke-width:0px;
    classDef bgSlate fill:#475569,color:#ffffff,stroke-width:0px;
AutomationView Icon AutomationView
calendar_month

Inside CIP Safety over EtherNet/IP: A Technical Guide

Replacing hardwired relays with networked safety devices brings immense flexibility to the plant floor. However, when engineers are tasked with implementing CIP Safety over EtherNet/IP, they quickly discover that sending SIL 3 data across a standard IT infrastructure introduces complex timing and verification challenges. Rather than assuming the underlying Ethernet network is infallible, the protocol […]

Read Article arrow_forward

Inside Beckhoff MX-System: The Cabinet-Free Automation Guide

Learning
%%{init: {'theme':'dark', 'themeVariables': { 'background': '#001c38' }}}%%
flowchart LR
    A["Power Feed Module"] --> B["MX Baseplate"]
    B --> C["IPC TwinCAT Runtime"]
    B --> D["Motion Drive Module"]
    B --> E["Decentralized I/O"]
    C -->|EtherCAT| D
    C -->|EtherCAT| E
AutomationView Icon AutomationView
calendar_month

Inside Beckhoff MX-System: The Cabinet-Free Automation Guide

Control cabinet assembly remains one of the largest labor bottlenecks in machine building. Traditional automation panels demand extensive manual layout, point-to-point wiring, DIN-rail terminal blocks, and active air conditioning units to dissipate thermal loads. The Beckhoff MX-System shifts this paradigm by replacing sheet-metal enclosures with an IP67-rated, modular platform mounted directly on the machine frame. […]

Read Article arrow_forward